Scope Of Application
- One installation method: Floor standing mounted ;
- Adopt AC 220VAC input; The main control board uses a single-chip microcomputer with an embedded operating system, the charging mode is plug and play;
- Using LED lights with different colors and different flash frequencies to indicate the current state of the charger;
- Using WIFI module to interact with the user’s mobile phone or laptop and other devices through wireless communication;
- Use the web and app to set the charging current, remotely stop charging, and monitor charging data;
- The shape adopts an ABS plastic structure.
Model No. | AF-AC-07-L-A-O-1-SF | |
Specification | Rated Power | 7KW |
Charging Device | Installation Method | Floor-Standed |
Feeding Method | Bottom in and bottom out | |
Equipment Dimension | 304*191*95 mm | |
Equipment Weight | 3 KGS | |
Cable Length | 5m ( Optional ) | |
Electrical Indicators | Input Voltage | AC 220V±20%; L+N+PE |
Input Frequency | 50 Hz ±10% | |
Output Voltage | AC 220V±20% | |
Output Current | 32 A | |
Current Limit Protection Value | ≥110% | |
Electrical Indicators | ≥11 | |
Metering Accuracy | 1.0 Level | |
Functional Design
| HMI | LED indicator strip |
Charging Mode | / | |
Mode of Payment | APP | |
Charging Method | Plug and charge | |
Operation Mode | / | |
Networking Method | Bluetooth / WIFI / APP | |
Safety Design | Operative Norm | IEC 61851-1:2017; IEC 62196-2:2016 |
Safety Function | Overvoltage protection, undervoltage protection, overload protection.grounding protection, overcurrent protection, leakage protection, overtemperature protection. | |
Environmental Indicators | Working Temperature | -20℃~+50℃ |
Working Humidity | 5%~95% non-condensing frost | |
Working Altitude | ≤2000m | |
Ingress Protection | IP54 | |
Cooling Method | Natural air cooling | |
Noisy Control | ≤40dB | |
MTBF | 30,000hours | |
Meaning of LED indicator
No. | State | Led Color |
1 | Charging | Blue Breathing Lighting |
2 | Prepare Charging | Constant Blue Lighting |
3 | Pause | Flashing Blue |
4 | Standby | Green Breathing Lighting |
5 | POST (Power on self-test) | Constant White Lighting |
No. | State | Led Color | Instructions | Recover The Fault |
1 | CP Exception | Red | Flash once in 5s | Pull out the plug |
2 | PE Exception | Red | Flash twice in 5s | Turn off the power |
3 | Normal Fault | Red | Constant Lighting | Pull out the plug |
Scope Of Application
The AC charging station provides AC power with AC 50Hz and rated voltage 220V.
Charging electric vehicles with on-board chargers is mainly suitable for the following places:
- Large, medium, and small electric vehicle charging stations;
- All kinds of electric vehicle parking spaces Public places, such as urban residential quarters, shopping plazas, power business places, etc.;
- High-speed service areas, stations, docks, and other transportation hub areas;
- Real estate and engineering Construction acceptance needs.
Working Environment
- The ambient air temperature during operation is -25℃~﹢50℃, 24h daily average temperature≤35℃( Too high or too low temperature will affect the life of the product );
- The average relative humidity≤90%(25℃ ), no condensation on the surface;
- Pressure: 80 kpa~110 kpa;
- Installation vertical inclination≤5%;
- Experimental level of Vibration and shock in use≤I Level, Inductive strength of an external magnetic field in either direction≤55mT;
- There should be no explosive medium in the place of use, and the surrounding medium should not notcontain harmful gases and conductive media that corrode metals and damage insulation, and is not allowed to be filled with water vapor and serious mold bacteria;
- The place of use should avoid direct sunlight. When installing outdoors, it is recommended to and sunshade facilities to the charging station to prolong the service life of the equipment;
When users have special requirements, please negotiate with our company.
Product Parameter
EV AC Charging Pile Parameter Table
Meaning of LED indicator
No. | State | Led Color |
1 | Charging | Blue Breathing Lighting |
2 | Prepare Charging | Constant Blue Lighting |
3 | Pause | Flashing Blue |
4 | Standby | Green Breathing Lighting |
5 | POST (Power on self-test) | Constant White Lighting |
No. | State | Led Color | Instructions | Recover The Fault |
1 | CP Exception | Red | Flash once in 5s | Pull out the plug |
2 | PE Exception | Red | Flash twice in 5s | Turn off the power |
3 | Normal Fault | Red | Constant Lighting | Pull out the plug |
Installation Of Equipment
Check the packing box for the following items before installation (subject to the packing list)
- Floor standing mounted type AC charging station(1 set )
- Installation instructions (1 set)
- 1 piece of certificate of quality
- Mounting expansion screws (1 pack)
Installation Environment Requirements
- TheIngress Protection of this series EV AC charging station: IP54;
- Ambient temperature -20℃to +50℃;
Common Faults And Solutions Of EV AC Charger Station
Serial Number | Common Malfunctions | Method Of Exclusion |
1 | When the gun is inserted,the interface does not show the connection or the information of “Please start charging by swiping your card” | Please check whether the charging gun is reliably connected to the vehicle and whether the gun lock is locked. |
2 | Swiping the card to start charging, after a while, it stops by itself | Generally, it is a communication problem, so when you finish swiping the card, record it yourself and try again with a different gun. If it happens repeatedly, report it to the manufacturer in time. |
3 | Locking phenomenon | At the end of charging, remember to swipe the card for settlement. If the card is locked, please swipe the card at the machine that was charged last time, and you can unlock it after the last charging fee is settled. |
4 | Jumping gun phenomenon | When swiping the card, confirm that the IC card balance is sufficient. If the balance is insufficient during the charging process, the charging will be automatically terminated. |
5 | After charging, the gun is locked and cannot be pulled out | Restart the charging process and wait for the gun to jump after the power is off. If this method is still unplugged, immediately contact the manufacturer for maintenance. |
6 | Start charging, the ammeter does not display the working current | Please check whether the phase line and neutral line of the electric energy meter are connected reversely or wrongly. |
7 | After power on, the display does not light up | If the indicator light is on and the display is not on, replace the display. |
8 | Not grounded | Under normal grounding conditions: 1. When the gun is not inserted, the auxiliary voltage 12V lights up blue; 2. When the gun is inserted, the auxiliary voltage 6V lights up green. |
Maintenance And Preservation Of EV AC Charging Station
- Charging stations should be installed outdoors in enclosed areas.
- When the charging cycle is finished or when the user terminates the charging cycle disconnect
the cable before storing the cable and inserting the plug into the storage socket on the wall of the charger.
Please note: In the process of charging station transportation, the charging station is packed firmly and the loading and unloading direction is marked. It is forbidden to store and transport the charging station upside down. The charging unit should be adequately secured during transport to avoid strong vibration and turbulence to damage the outer packaging of the equipment.
Note: Non-professional personnel are strictly prohibited from installing the EV AC charger.
The AC charging station provides AC power with AC 50/60Hz and rated voltage 220V±20%.
Charging electric vehicles with on-board chargers is mainly suitable for the following places:
- Large, medium, and small electric vehicle charging stations;
- All kinds of electric vehicle parking spaces Public places, such as urban residential quarters, shopping plazas, power business places, etc.;
- High-speed service areas, stations, docks, and other transportation hub areas;
- Real estate and engineering Construction acceptance needs.
- The ambient air temperature during operation is -20℃~﹢50℃,24h daily average temperature≤35℃ ( Too high or too low temperature will affect the life of the product );
- The average relative humidity≤90%(25℃ ), no condensation on the surface;
- Pressure:80 kpa~110 kpa;
- Installation vertical inclination≤5%;
- Experimental level of Vibration and shock in use≤I Level, Inductive strength of an external magnetic field in either direction≤55mT;
- There should be no explosive medium in the place of use, and the surrounding medium does notcontain harmful gases and conductive media that corrode metals and damage insulation, and are not allowed to be filled with water vapor and serious mold bacteria;
- The place of use should avoid direct sunlight. When installing outdoors, it is recommended to addsunshade facilities to the charging stationto prolong the service life of the equipment;
When users have special requirements, please negotiate with our company.